Skip to main content

Technical specifications

The following tables contain technical specifications for DD500E and DD500E-R.

Device characteristics

Device detailsDD500E and DD500E-R
TypeDIN rail
Size55 (D) x 50 (W) x 75 (H) mm
Weight175g
Casing materialMetal
Operating voltage/power input+24VDC (External power supply, included) or
IEEE 802.3af (PoE)
External power supplyDD500E: Mean Well HDR-15-24
DD500E-R: Delta Chrome II DIN DRC-24V015W1RZ
Power2.5 W
PoE class 2
Ethernet ports100BASE-TX, RJ45 connectors
IEEE 802.3af, PoE
Configuration portsProprietary (configuration cables supplied)
Performance100 Mbps network interfaces
Throughput: 40 Mbps
Packet loss rate: less than 0.01% under normal load conditions
Ingress protectionIP40 (EN 60529)

Certifications

CertificationsDD500E and DD500E-R
CE, UKCA,
CAN ICES-3(b)/nmb-3(b)
Compliance with applicable directives for EU, UK and Canada
SafetyIEC/EN/UL 62368-1, IEC/EN 62368-3
FCC classificationFCC Subpart 15B/ICES003
VibrationIEC 60068-2-6, IEC 60068-2-64
ShockIEC 60068-2-27
EnvironmentalReach, RoHS, WEEE
EMCEN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019
Railway (DD500E-R only)EN 50121-4:2016, EN 50125-3:2004 (Climate Class TX), designed to maintain internal shelter temperatures within the defined operational thresholds.

Temperature ranges

Temperature rangesDD500E and DD500E-R
Operating temperaturePoE: -20°C to +65°C, 5–95% RH non-condensing
- Max time running on power redundancy: less than 2h with reduced max operating temperature +55°C
Power supply, DD500E: -20°C to +50°C, 5–95% RH non-condensing
- Max time running on power redundancy: less than 2h with max operating temperature +50°C
Power supply, DD500E-R: -40°C to +70°C, 5–95% RH non-condensing
- Max time running on power redundancy: less than 2h with reduced max operating temperature +50°C
Storage and transport-40°C to +85°C, 5–95% RH non-condensing
Loading...